30 – 630 HEIDENHAIN Service Manual iTNC 530
MP7481.x Sequence for new and returned tool when changing tools
Format: %xxxxxxxx
0: First, output the pocket of the tool to be returned
1: First, output the pocket of the new tool
Input: Bit 0: New tool from magazine 1
Bit 1: New tool from magazine 2
Bit 2: New tool from magazine 3
Bit 2: New tool from magazine 4
Bit 4: New tool from magazine 5
Bit 5: New tool from magazine 6
Bit 6: New tool from magazine 7
Bit 7: New tool from magazine 8
340 490-05
PLC
RUN
MP7481.0 Tool from magazine 1 to be returned
MP7481.1 Tool from magazine 2 to be returned
MP7481.2 Tool from magazine 3 to be returned
MP7481.3 Tool from magazine 4 to be returned
MP7481.4 Tool from magazine 5 to be returned
MP7481.5 Tool from magazine 6 to be returned
MP7481.6 Tool from magazine 7 to be returned
MP7481.7 Tool from magazine 8 to be returned
MP7482 Pocket coding of the tool magazine
Format: %xxxx
0: Variable pocket coding
1: Fixed pocket coding
Input: Bit 0: Magazine 1
Bit 1: Magazine 2
Bit 2: Magazine 3
Bit 3: Magazine 4
340 420-06
PLC
RUN
MP7483 Tool name/number for TOOL CALL / TOOL DEF
Input: 0: Names and numbers are permitted (as before)
1: Only names are permitted
2: Only numbers are permitted
340 490-03
MP7484 Search sequence in tool magazines
Input: 0 to 7 [index from MP7261]
-1: Abort
340 490-05
MP7485 Add usage time for tool selection
Input: 0 to 100 [%]
Sstandard setting: 10
340 490-05
MP7490 Functions for traverse ranges
Format: %xxxx
Input: Bit 0 –
0: Display one traverse range with MOD
1: Display three traverse ranges with MOD
Bit 1 –
0: Each traverse range has its own datum (and 3 memories for the positions of the
swivel head)
1: One datum for all traverse ranges
Bit 2 – Calibration data: touch probe for workpiece measurement:
0: One set of calibration data for all traverse ranges
1: Every traverse range has its own set of calibration data
Bit 3 – Calibration data: touch probe for tool measurement:
0: One set of calibration data for all traverse ranges
1: Every traverse range has its own set of calibration data
PLC
RUN
MP Function and input SW version
and
behavior