Note
• The displayed parameters may vary for
dierent access control devices.
• Some of the following parameters are not listed in the Basic Informaon page, click More to
edit the parameters.
Name
Edit the card reader name as desired.
Door Contact
You can set the door sensor as remaining closed or remaining open. Usually, it is remaining
closed.
Exit
Buon Type
You can set the exit buon as remaining closed or remaining open. Usually, it is remaining
open.
Door Locked Time
Aer swiping the normal card and relay acon, the mer for locking the door starts working.
Door Open Timeout Alarm
The alarm can be triggered if the door has not been closed in a
congured me period. If it is
set as 0, no alarm will be triggered.
Super Password
The
specic person can open the door by inpung the super password.
Extended Open Duraon
The door contact can be enabled with appropriate delay aer person with extended access
needs swipes her/his card.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer of the card reader (by entering
the dismiss code on the keypad).
Note
• The duress code, super code, and dismiss code should be
dierent.
• The duress code, super password, and the dismiss code should be dierent from the
authencaon password.
• The length of duress code, super password, and the dismiss code is according the device,
usually it should contains 4 to 8 digits.
5. Click OK.