147
Ref.
Code
Register Channel
Type Function Value Remark
49001 NA
Unsigned short
Selected Target Point Number (TPN)
(Note: Set TPN as enabled point# before
reading point# parameters using function code
0x06 with the same register 9001)
1-60
New for
ACM150 G2
49002 NA
Unsigned short
Error Code for Target Point Parameters
-
49003-49018 NA
Point name (Location) of TPN.
-
49019 NA
Unsigned short
Bitmap for gas #1~#16:
bit[15]:gast#16 status …bit[0]:gas#1 status
0x0000 ~ 0xFFFF
New for
ACM150 G2
49101-49116 NA
Gas name of Gas#1 on TPN.
-
49117-49120 NA
Gas unit of Gas#1 on TPN.
-
49121-49122 NA
Float
(Mid-Little Endian)
Alarm2 threshold of Gas#1 on TPN.
-
49123-49124 NA
Float
(Mid-Little Endian)
Alarm1 threshold of Gas#1 on TPN.
-
49141-49156 NA
Gas name of Gas#2 on TPN.
-
49157-49160 NA
Gas unit of Gas#2 on TPN.
-
49161-49162 NA
Float
(Mid-Little Endian)
Alarm2 threshold of Gas#2 on TPN.
-
49163-49164 NA
Float (Mid-Little
endian)
Alarm1 threshold of Gas#2 on TPN.
-
49701-49716 NA
Gas name of Gas#16 on TPN.
-
49717-49720 NA
Gas unit of Gas#16 on TPN.
-
49721-49722 NA
Float
(Mid-Little Endian)
Alarm2 threshold of Gas#16 on TPN.
-
49723-49724 NA
Float
(Mid-Little Endian)
Alarm1 threshold of Gas#16 on TPN.
-