4.
C300 CONTROLLER CONFIGURATION .............................. 43
4.1 Configuration overview ............................................................................ 44
Configuration Studio ............................................................................................................ 44
Define and add assets in your enterprise model ....................................................................... 44
FTE system configuration .......................................................................................................... 44
Specifying a Time Server ................................................................................................................ 45
C300 Controller Device Index .................................................................................................... 45
4.2 Create C300 Controller and CEE function blocks ............................... 46
4.3 Configure CEEC300 block ........................................................................53
4.4 Configure a Secondary C300 Controller block .....................................58
4.5 Convert a non-redundant C300 Controller to a redundant controller ....... 60
4.6 Convert a redundant C300 Controller to a non-redundant controller ....... 63
4.7 Configure IOLINK function blocks ....................................................... 64
4.8 Import/export C300 Controller configuration ....................................... 67
4.9 Reset Device Index and IP address of a controller ...................................... 67
4.10 Create a Control Module.................................................................... 69
4.11 Assign Control Modules and IOMs to a CEEC300 block ......................... 72
4.12 Copy Control Modules ..........................................................................78
4.13 Assign I/O Modules to C300 IOLINK blocks.......................................80
4.14 Add an I/O Channel to a Control Module ......................................... 84
5.
C300 CONFIGURATION FORM REFERENCE ........................... 87
5.1 C300 Controller Block ...............................................................................87
Main tab ............................................................................................................................... 87
Redundancy tab ................................................................................................................... 91
System Time tab ........................................................................................................................ 95
Statistics tab ........................................................................................................................ 96
Peer Connections tab .......................................................................................................... 98
Hardware Information tab ..................................................................................................... 99
FTE tab ..................................................................................................................................... 100
UTP/TCP tab ......................................................................................................................104
IP/ICMP tab ........................................................................................................................106
Soft Failures tab ..................................................................................................................110
Server History tab ...............................................................................................................112

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell C300 and is the answer not in the manual?

Honeywell C300 Specifications

General IconGeneral
Memory512 MB RAM, 512 MB Flash
TypeProcess Controller
Communication PortsEthernet, Serial
Power Supply24V DC
InputsAnalog and Digital
OutputsAnalog and Digital
CommunicationEthernet, Serial, HART
RedundancySupported (Hot Standby)