Configuring via the Web Server
Configuring the Doors
NetAXS™ Access Control Unit User’s Guide, Document 800-00233, Revision A 2-23
Steps
:
1. Use the descriptions in the table below to configure the General reader
settings.
Table 2-4: Configuration > Doors > Reader Tab Descriptions
Setting Description
Access Mode Specifies the validation conditions required at the door before
access is granted. For each access mode, you must also select a
time zone from the drop down list. The time zone is the schedule
by which the access mode is effective.
Disabled – Allows neither exit nor entry by Card and PIN mode
or Card or PIN mode. Also, free egress is not allowed.
Lockdown – Denies door entry but allows egress.
Card OnlyGrants access with only a successful card read.
Pin Only – Grants access with only a valid PIN number entered
at the doors keypad.
Card or Pin – Grants access with either a successful card read or
a valid PIN number entry at the doors keypad.
Card and Pin – Grants access only with both a successful card
read and a valid PIN entry at the door’s keypad. You can
perform the card read and PIN entry in either sequence.
Supervisor – Enables a supervisor to enter without allowing
access to others. When the supervisor presents his card during
the time zone just once, he gains access but does not enable
access for non-supervisory personnel. If the supervisor presents
his card twice, he enables access for all non-supervisory
personnel as well. After the supervisor presents his card twice to
allow general access, he can disable the general access for the
time zone by presenting his card again twice consecutively.
Escort – Requires a supervisor escort for a non-supervisor
cardholder. The supervisor must present his card first, then the
non-supervisor must present his card within ten seconds of the
supervisors card read.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell NetAXS and is the answer not in the manual?

Honeywell NetAXS Specifications

General IconGeneral
CategoryControl Unit
Max. Number of Doors4
Max. Number of Readers8
Inputs8
Outputs4
Users10, 000
Transaction Buffer50, 000
Operating Voltage12-24 VDC
Network Interface10/100 Mbps Ethernet
Reader TechnologyMagnetic Stripe, Barcode, Proximity, Smart Card
CommunicationTCP/IP, RS-485
Humidity5% to 85% RH, non-condensing
Weight3.5 lbs
CertificationsUL294, CE, FCC
Dimensions165 mm x 140 mm x 40 mm (6.5" x 5.5" x 1.6")

Related product manuals