Configuring via the Web Server
Configuring the Doors
NetAXS™ Access Control Unit User’s Guide, Document 800-00233, Revision A 2-27
6. If you want to change an existing card format’s data layout, double-click the
format’s name on the list of existing formats to display the Card Format Data
Layout screen. Use the descriptions in the table above to edit the layout’s
fields. Then, click
Update (to save in the format’s current name) or Save as (to
save with a different format name) to save the edited format. To return to the
default settings for the card format, click
Reset. To delete the card format, click
Delete.
Site Code D Lists where on the card the Site Code A is listed. Consult
the card manufacturer for detail on the card detail.
Start Bit – first bit in the card where the card’s Site Code
begins.
Num Bits – Number of bits to the right of the start bit,
including the start bit, that comprise the Site Code.
Most card formats require only Site Code A.
Issue Code Lists where on the card the Issue Code A is listed.
Start Bit – first bit in the card where the card’s Issue Code
begins.
Num Bits – Number of bits to the right of the start bit,
including the start bit, that comprise the Issue Code.
Most cards do not contain an Issue Code.
Table 2-5: Configuration > Doors > Reader > Card Format Fields (continued)
Setting Description