Table 5-15 Processor Events That Light System Insight Display LEDs (continued)
NotesSourceCauseSample IPMI EventsDiagnostic
LED(s)
Threshold
exceeded for
WIN AgentToo many
corrected
Type E0h, 5824d:26d
PFM_CORR_ERROR_MEM
Processors
cache errorserrors detected
by platform from
processor
corrected by
zx2
Power Pod
voltage is out
BMCVoltage on
CRU is
inadequate
Type 02h, 02h:07h:03h
VOLTAGE_DEGRADES_TO_NON_RECOVERABLE
Processors
of range
(likely too
low)
Table 5-16 Processor Events That May Light System Insight Display LEDs
NotesSourceCauseSample IPMI EventsDiagnostic
LED(s)
SFWInstalled
processors are
not compatible
Type E0h, 734d:26d
BOOT_CPU_LOADING_ERROR
Processors
SFWProcessors
and/or
Type E0h, 2953d:26d
BOOT_CPU_LOADING_ERROR
Processors
termination out
of order
SFWA logical CPU
(thread) failed
late self test
Type E0h, 36d:26d
BOOT_CPU_LATE_TEST_FAIL
Processors
SFWA logical CPU
(thread) slave
Type E0h, 677d:26d
MC_RENDEZVOUS_SLAVES_FAIL
Processors
failed to
rendezvous
SFWA CPU core
failed the
Type E0h, 30d:26d
BOOT_CPU_CONFIG_FAIL
Processors
configuration
process
SFWA processor
fixed core
Type E0h, 790d:26d
BOOT_CPU_BAD_CORE_FIXED_RATIO
Processor
frequency ratio
is incompatible
with bus
frequency
SFWA watchdog
timer expired
Type E0h, 745d:26d
BOOT_FINAL_RENDEZ_WATCHDOG_FAIL
Processor
and determined
that a monarch
processor is not
responding.
Bad or slow
processor
SFWA logical CPU
(thread)
Type E0h, 83d:26d
BOOT_RENDEZ_FAILURE
Processors
rendezvous
failure
SFWThe logical
monarch CPU
Type E0h, 67d:26d
BOOT_MONARCH_TIMEOUT
Processors
126 Troubleshooting