Temperature, humidity, and sound power levels are provided in Table 2-5 while minimum,
maximum, and typical configurations are in Table 2-6 (page 40) and Table 2-7 (page 41).
NOTE: De-rate maximum dry bulb temperature 1 degree/300 meters (1000 feet) above 900
meters 3000 feet).
Table 2-5 Environmental Specifications (system processing unit with hard disk)
ValueParameter
+5˚ C to +35˚ C (+41˚ F to +95˚ F)Operating temperature
- 40˚ C to +60˚ C (-40˚ F to +140˚ F)Storage temperature
+38˚ C (+100˚ F)Over-temperature shutdown
20% to 80% relative (non-condensing)Operating humidity
90% relative (non-condensing) at + 65˚ CStorage humidity
Office Friendly ServerData Center ServerAcoustic Noise Emission (ISO 9296)
LwAd = 5.9 BLwAd = 6.8 BTypical configuration (disk
idle)
1
Sound Power Level
LwAd = 5.9 BLwAd = 6.8 BMaximum configuration
(disk idle)
2
LwAd = 5.9 BLwAd = 7.0 BMaximum configuration
(disk active)
3
LpAm = 41.4 dBLpAm = 51.6 dBSound Pressure Level
Altitude
0 to 3000 m (10,000 ft.) maximumOperating altitude
0 to 4572 m (15,000 ft.) maximumStorage altitude
1 Typical configuration at room temperature (25˚C).
2 Single processor, one to two SCSI hard disk drives and less than 8 GB of memory.
3 Dual processor, three SCSI hard disk drives and more than 8 GB of memory.
Table 2-6 (page 40) shows the physical and environmental specifications for the Data Center
server.
Physical and Environmental Specifications 39