EasyManuals Logo

HP integrity rx2800 i4 User Manual

HP integrity rx2800 i4
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
A Utilities
SAS disk setup
Using the saupdate command
The saupdate command is used to query or change the mode of the Smart Array P410i and
Smart Array P411 controllers to HBA or RAID. Querying or changing modes is not supported for
other controllers.
The newly added commands to SAUPDATE are:
• Get Mode
• Set Mode
Get mode
This command displays the current mode of the controllers.
Syntax
saupdate get_mode <controller>
<controller> can be any one of the following strings.
Table 44 <controller> strings
Meaning<controller>
A controller having the PCI segment id, bus id, device id and function id is addressed<seg:bus:dev:func>
Addresses all controllers in the systemall
Controllers of a particular type indicated by the <model> string are addressed<model>
Figure 40 saupupdate get_mode
Set mode
IMPORTANT: If you are using HBA mode, do not install any disk that has previously been a part
of a RAID volume into the system.
Set mode is used to change the mode of the controller. If the controller is already in the required
mode the following message appears:
The controller at seg:bus:dev:funcis already in HBA|RAID mode.
HP Confidential SAS disk setup 137

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP integrity rx2800 i4 and is the answer not in the manual?

HP integrity rx2800 i4 Specifications

General IconGeneral
Number of Processors1 or 2
Memory Slots24 DIMM slots
Processor Cores4 or 8 per processor
Cache32 MB L3 per processor
MemoryUp to 384 GB DDR3
StorageUp to 8 SFF SAS/SATA drives
RAID SupportRAID 0, 1, 5, 6
NetworkIntegrated 10/100/1000Base-T Ethernet
Network ControllerHP NC382i
Expansion Slots6 PCIe 2.0 slots
Power SupplyHot-plug redundant power supplies
Operating SystemsHP-UX, Linux
Form Factor2U Rack
Processor Speed1.73 GHz, 2.13 GHz, or 2.53 GHz