EasyManua.ls Logo

HP Integrity Superdome 2 16-socket - Show Blade PowerDelay

HP Integrity Superdome 2 16-socket
217 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE: SERVER is a valid alias for BLADE.
Description:
Displays the port mapping for the blade specified by the bay number
Access level/Bay level:
All
Bay specific
Restrictions:
You must have access to the specified bay number.
This command is not applicable to storage blades.
Example:
OA-0018FE27577F> SHOW SERVER PORT MAP
Mezz
Mezz Mezz Device Port Interconnect Interconnect
Slot Device Port Status Bay Bay Port Device ID
------------------------------- Blade 001 ---------
<
absent>
------------------------------- Blade 02A ---------
1 Not Present
Embed Embedded Ethernet
Port 1 OK Bay 1 Port 2 55:1E:0B:91:8F:02
Port 2 No Connect Bay 2 Port 2 55:1E:0B:91:8F:03
------------------------------- Blade 02B ---------
1 Not Present
Embed Embedded Ethernet
Port 1 OK Bay 1 Port 10 00:1E:0B:92:20:6E
Port 2 No Connect Bay 2 Port 10 00:1E:0B:92:20:6F
SHOW BLADE POWERDELAY
Command:
SHOW BLADE POWERDELAY {ALL | <bay number> [{ - | , } <bay number>]}
NOTE: SERVER is a valid alias for BLADE.
Description:
Displays the PowerDelay status for the specified server blade or range of server blades
Access level/Bay level:
All
Bay specific
SHOW BLADE POWERDELAY 101