EasyManua.ls Logo

HP Integrity Superdome 2 16-socket - Set Date; Set NTP Primary

HP Integrity Superdome 2 16-socket
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SET DATE
Command:
SET DATE MMDDhhmm [[CC]YY][TZ]
Description:
Sets the date of the complex with the following definitions:
MM: Month
DD: Day
hh: Hour (24-hour time)
mm: Minute
CC: Century
YY: Year
TZ: Time zone
If you leave the time zone variable blank, then the current time zone is left in effect.
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
You must be connected to the monarch OA.
Date and time can only be set if NTP is disabled.
MM is an integer from 01 to 12.
DD is an integer from 01 to 31.
hh is an integer from 00 to 24.
mm is an integer from 00 to 60.
For valid time zones, see “Time zone settings” (page 207).
SET NTP PRIMARY
Command:
SET NTP PRIMARY <ip address>
Description:
Sets the primary server used for synchronizing time and date using the NTP protocol
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
You must be connected to the monarch OA.
The <ip address> must be in the form ###.###.###.###, where each ### ranges
from 0 to 255.
94 Complex management commands

Table of Contents

Other manuals for HP Integrity Superdome 2 16-socket

Related product manuals