SET DATE
• Command:
SET DATE MMDDhhmm [[CC]YY][TZ]
• Description:
Sets the date of the complex with the following definitions:
◦ MM: Month
◦ DD: Day
◦ hh: Hour (24-hour time)
◦ mm: Minute
◦ CC: Century
◦ YY: Year
◦ TZ: Time zone
If you leave the time zone variable blank, then the current time zone is left in effect.
• Access level/Bay level:
OA Administrator, OA Operator
• Restrictions:
You must be connected to the monarch OA.◦
◦ Date and time can only be set if NTP is disabled.
◦ MM is an integer from 01 to 12.
◦ DD is an integer from 01 to 31.
◦ hh is an integer from 00 to 24.
◦ mm is an integer from 00 to 60.
◦ For valid time zones, see “Time zone settings” (page 207).
SET NTP PRIMARY
• Command:
SET NTP PRIMARY <ip address>
• Description:
Sets the primary server used for synchronizing time and date using the NTP protocol
• Access level/Bay level:
OA Administrator, OA Operator
• Restrictions:
You must be connected to the monarch OA.◦
◦ The <ip address> must be in the form ###.###.###.###, where each ### ranges
from 0 to 255.