The Dynamic Power Savings mode is established at the complex level and is managed
from the Monarch OA. A change in Dynamic Power Savings mode is propagated to all
OAs in the complex.
Automatically turns on additional supplies as needed in response to rapid increases in
load.
NOTE: This setting does not impact the power mode or redundancy settings.
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
None
SET TIMEZONE
Command:
SET TIMEZONE "<timezone>"
Description:
Sets the time zone
See Time zone settings (“Time zone settings” (page 207)) for appropriate time zones. Some
that are commonly used include: CET, CST6CDT, EET, EST, EST5EDT, GB, GMT, HST, MET,
MST, MST7MDT, NZ, PRC, PST8PDT, UCT, and UTC.
Access level/Bay level
OA Administrator, OA Operator
Restrictions:
None
SHOW CONFIG
Command:
SHOW CONFIG
Description:
Displays the script required to recreate the settings of the enclosure. Passwords are not included
for any user.
Access level/Bay level:
OA Administrator
Restrictions:
None
Example:
sphere-oa> show all
>SHOW CONFIG
#Script Generated by Administrator
#Generated on: Tue May 4 15:16:06 2010
#Set Enclosure Time
SET TIMEZONE 77