POWEROFF INTERCONNECT
• Command:
POWEROFF INTERCONNECT {ALL | <bay number> [{ - | , } <bay number>]}
• Description:
Sends a request to power off the interconnect module
• Access level/Bay level:
Administrator, operator◦
◦ Bay specific
• Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.
POWERON INTERCONNECT
• Command:
POWERON INTERCONNECT {ALL | <bay number> [{ - | , } <bay number>]}
• Description:
Powers on the specified interconnect
• Access level/Bay level:
Administrator, operator◦
◦ Bay specific
• Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.
RESTART INTERCONNECT
• Command:
RESTART INTERCONNECT <bay number>
• Description:
Resets the interconnect tray in the specified bay
• Access level/Bay level:
Administrator, operator◦
◦ Bay specific
• Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.