POWEROFF INTERCONNECT
Command:
POWEROFF INTERCONNECT {ALL | <bay number> [{ - | , } <bay number>]}
Description:
Sends a request to power off the interconnect module
Access level/Bay level:
Administrator, operator
Bay specific
Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.
POWERON INTERCONNECT
Command:
POWERON INTERCONNECT {ALL | <bay number> [{ - | , } <bay number>]}
Description:
Powers on the specified interconnect
Access level/Bay level:
Administrator, operator
Bay specific
Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.
RESTART INTERCONNECT
Command:
RESTART INTERCONNECT <bay number>
Description:
Resets the interconnect tray in the specified bay
Access level/Bay level:
Administrator, operator
Bay specific
Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.