Loading...
Enclosure IP Mode: Not Supported
SHOW OA STATUS
Command:
SHOW OA STATUS [ALL | <bay number> [{ , | - } <bay number>]]
Description:
Displays health status for the Onboard Administrator. If you do not specify the Onboard
Administrator, the command defaults to the Active Onboard Administrator.
Access level/Bay level:
All
Restrictions:
None
Example:
sphere-oa2> show oa status
Onboard Administrator #2 Status:
Name: sphere-oa2
Role: Active
UID: Off
Status: OK
Diagnostic Status:
Internal Data OK
Firmware Mismatch OK
SHOW POWER
Command:
SHOW POWER
Description:
Displays the current power configuration
Access level/Bay level:
All
Restrictions:
None
Example:
sphere-oa2> show power
Power Mode: Redundant
Dynamic Power: Enabled
Set Power Limit: Not Set
Power Capacity: 14400 Watts DC
Power Available: 12775 Watts DC
Power Allocated: 1625 Watts DC
Present Power: 1161 Watts AC
Power Limit: 17510 Watts AC