14 Blade management commands
SET NIC
Command:
SET NIC {AUTO | FORCED}
Description:
Configures the external NIC for auto-negotiation or forced link settings.
Access level/Bay level:
OA Administrator
Restrictions:
None
SET BLADE POWERDELAY
Command:
SET BLADE POWERDELAY {ALL | <bay number> [{ - | , } <bay number>]}
{number of seconds to delay power | NOPOWERON}
NOTE: SERVER is a valid alias for BLADE.
Description:
Set the PowerDelay status of the specified server or range of servers. If the delay is zero, the
delay has no effect on the device. If the delay is NOPOWERON, then the device cannot power
on until all devices have completed the delays.
Access level/Bay level:
Administrator
Bay specific
Restrictions:
You must have access to the specified bay number.
SET BLADE UID
Command:
SET BLADE UID {ALL | <bay number> [{ - | , } <bay number>]} {ON | OFF}
NOTE: SERVER is a valid alias for BLADE.
Description:
Turns a server blade UID LED on or off
Access level/Bay level:
All
Bay specific
Restrictions:
You must have access to the specified bay number.