SET ENCLOSURE NAME
Command:
SET ENCLOSURE NAME "<enclosure name>"
Description:
Changes the enclosure name.
The default enclosure name is the mid-plane serial number.
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
The <enclosure name> must be 1 to 32 characters long and includes all alphanumeric,
underscore (_), and dash (-) characters.
SET ENCLOSURE PART_NUMBER
Command:
SET ENCLOSURE PART_NUMBER "<part number>"
Description:
Sets the part number of the enclosure
Access level/Bay level:
OA Administrator
Restrictions:
Must be 10 characters in length and the first character must be a digit. Acceptable characters
are all alphanumeric and the dash (-).
SET ENCLOSURE PDU_TYPE
Command:
SET ENCLOSURE PDU_TYPE {1|2|3|4}
Description:
Sets the enclosure PDU type to:
1 = Single-phase
2 = Three-phase
3 = Three-phase, international
4 = DC Power Input Module
Access level/Bay level:
OA Administrator
Restrictions:
Only 1, 2, 3, 4 are valid PDU types.