Operation Manual – SNMP
Quidway S3100 Series Ethernet Switches Chapter 1
SNMP Configuration
Huawei Technologies Proprietary
1-5
Operation Command Description
Set the device engine ID
snmp-agent
local-engineid engineid
Optional
By default, the device
engine ID is
"Enterprise Number +
device information".
Create or update the view
information
snmp-agent mib-view
{ included | excluded }
view-name oid-tree
Optional
By default, the view
name is ViewDefault
and OID is 1.
Table 1-3 Configure SNMP basic functions (SNMP V3)
Operation Command Description
Enter system view
system-view
—
Enable SNMP Agent
snmp-agent
Required
By default, SNMP
Agent is disabled.
Set system information
snmp-agent sys-info
{ contact sys-contact |
location sys-location |
version { { v1 | v2c |
v3 }* | all } }
Optional
By default, the contact
information for system
maintenance is "R&D
Beijing, Huawei
Technologies Co.,
Ltd.", the system
location is "Beijing
China", and the
SNMP version is
SNMP V3.
Set an SNMP group
snmp-agent group v3
group-name
[ authentication |
privacy ] [ read-view
read-view ] [ write-view
write-view ] [ notify-view
notify-view ] [ acl
acl-number ]
Required
Add a new user for an SNMP
group
snmp-agent usm-user
v3 user-name
group-name
[ authentication-mode
{ md5 | sha }
auth-password
[ privacy-mode des56
priv-password ] ] [ acl
acl-number ]
Required

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S3100 Series and is the answer not in the manual?

Huawei Quidway S3100 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S3100 Series
CategorySwitch
LanguageEnglish

Related product manuals