Operation Manual – Login
Quidway S3100 Series Ethernet Switches Chapter 7 Controlling Login Users
Huawei Technologies Proprietary
7-6
7.3.3 Configuration Example
I. Network requirements
Only SNMP users sourced from the IP addresses of 10.110.100.52 and 10.110.100.46
are permitted to access the switch.
II. Network diagram
InternetInternet
Sw itc hSw itc h
s
Figure 7-2 Network diagram for controlling SNMP users using ACL
III. Configuration procedure
# Define a basic ACL.
<Quidway> system-view
[Quidway] acl number 2000 match-order config
[Quidway-acl-basic-2000] rule 1 permit source 10.110.100.52 0
[Quidway-acl-basic-2000] rule 2 permit source 10.110.100.46 0
[Quidway-acl-basic-2000] rule 3 deny source any
[Quidway-acl-basic-2000] quit
# Apply the ACL to only permit SNMP users sourced from the IP addresses of
10.110.100.52 and 10.110.100.46 to access the switch.
[Quidway] snmp-agent community read huawei acl 2000
[Quidway] snmp-agent group v2c huaweigroup acl 2000
[Quidway] snmp-agent usm-user v2c huaweiuser huaweigroup acl 2000
7.4 Controlling Web Users by Source IP Address
You can manage a Quidway series Ethernet switch remotely through Web. Web users
can access a switch through HTTP connections.
You need to perform the following two operations to control Web users by source IP
addresses.
z Defining an ACL
z Applying the ACL to control Web users

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S3100 Series and is the answer not in the manual?

Huawei Quidway S3100 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S3100 Series
CategorySwitch
LanguageEnglish

Related product manuals