Operation Manual – Login
Quidway S3100 Series Ethernet Switches Chapter 3 Logging in through Telnet
Huawei Technologies Proprietary
3-12
Note that if you configure to authenticate the users in the scheme mode, the command
level available to users logging into a switch depends on the authentication-mode
{ password | scheme | none } command, the user privilege level level command, and
the service-type { ftp [ ftp-directory directory ] | lan-access | { ssh | telnet |
terminal }* [ level level ] } command, as listed in
Table 3-7.
Table 3-9 Determine the command level when users logging into switches are
authenticated in the scheme mode
Scenario
Authentication mode User type Command
Command
level
The user privilege
level level command is
not executed, and the
service-type command
does not specify the
available command
level.
Level 0
The user privilege
level level command is
not executed, and the
rvice-type command
fies the available
command level.
se
speci
Determined
by the
service-type
command
The user privilege
l level command is
executed, and the
service-type command
does not specify the
available command
level.
leve
Level 0
VTY users
that are
AAA&RADIUS
authenticated
or locally
authenticated
The user privilege
level level command is
executed, and the
service-type command
specifies the available
command level.
Determined
by the
service-type
command
The user privilege
el level command is
xecuted, and the
service-type command
does not specify the
available command
level.
lev
not e
Scheme
(authentication-mode
scheme)
VTY users
that are
authenticated
in the RSA
mode of SSH
The user privilege
level level command is
not executed, and the
service-type command
specifies the available
command level.
Level 0