S1700 Managed Series Ethernet Switches 
Web User Manual 
Huawei Proprietary and Confidential           
Copyright © Huawei Technologies Co., Ltd. 
 
Step 2  Select checkbox on the left of interface “GigabitEthernet0/0/1" in interface list and then click 
Configure button.The configuration page is shown as below. 
Figure 5-29 STP Settings Based on Interface 
 
 
Table 5-18 Parameters of STP Settings Based on Interface 
Select instance number on interface. 
Definition of this interface‟s priority in spanning tree. A higher priority 
will specify firstly interface to forwarding packet. The lower number 
indicates the higher priority. If all interfaces‟ path cost is the same on 
this switch, the higher priority interface will be configured as the active 
link in the spanning tree. The default value is 128; range is 0~240; field 
is 16. 
The root cost when switch reaching to CIST region.