5 - C P
Control Panel
Screen alerts and instructions
F4 – Confi guration
Access level: Erector / Dismantler
Access level: Erector / Dismantler
1
2
3
4
1
2
3
4
1
2
3
4
OK button to
confi rm change
Note: Numbers on the above option buttons are displayed as an example only. Actual messages displayed may diff er
from picture.
Option
button (4)
Navigation
button
Option Choice Description
PROGRAM 200 / 300
Option to select model of unit used in current confi guration
F200 select 200
F300 select 300
LINK OPTION
LINKED / UNLINKED /
TWIN COM
F200 must be set to LINKED at all times
F300 LINKED when unit is used in a linked confi guration
UNLINKED when unit is used in an unlinked confi guration
TWIN COM when two units are used in a bearing bridge
confi guration and must be controlled by a single
operator using a communication cable
LINK DOOR ENABLE / DISABLE
F200 DISABLE default setting unless a switched door is required
F300 DISABLE when unit is used in a linked confi guration
ENABLE when unit is used in an unlinked confi guration
DOOR SWITCH ENABLE / DISABLE
DISABLE default setting
used when no switched door is required
ENABLE used when a switched door is required
ELECTRIC MODE ENABLE / DISABLE
ENABLE when control panel is used on an electrical unit
DISABLE when control panel is used on gas-powered unit
INCLINOMETER 1 ENABLE / DISABLE
DISABLE when unit is used in a single unit confi guration
ENABLE when unit is used in a bearing bridge confi guration
and inclinometer on the twin mast adapter is
plugged into INCLINOMETER 1 port on the panel
INCLINOMETER 2 ENABLE / DISABLE
DISABLE when unit is used in a single unit confi guration
ENABLE when unit is used in a bearing bridge confi guration
and inclinometer on the twin mast adapter is
plugged into INCLINOMETER 2 port on the panel
OPERATOR PWD VALUE
Option available to qualifi ed E&D personnel to modify operator (entry
level) password
RESET RUNTIME NORMAL / RESET Option to reset the runtime counter of the unit
PASSWORD ENABLE / DISABLE
Option to enable or disable the operator password (entry level); when
DISABLED, other means must be put in place to prevent unauthorized
operation when the operator is not present
INACTIVITY VALUE
Delay time in seconds after which the screen will return to alarms
page if no buttons are pressed
LEVEL 1
Option available to qualifi ed E&D personnel to modify Level 1 E&D
password