EasyManua.ls Logo

Hypertherm XPR170 - Replace a Pressure Transducer

Hypertherm XPR170
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Torch Connect Console
3
XPR170 Field Service Bulletin 810410 107
Replace a pressure transducer
Refer to Torch connect console manifold side – view 1 on page 153 for
location and part number.
1. Complete the following procedures:
a. Remove the power from the cutting system.
b. Remove the gas pressure from the cutting system.
c. Remove the top panel.
d. Remove the manifold-side panel.
Refer to Torch connect console top panel and side panels on page 126.
Keep all nuts and screws that you remove.
2. Disconnect the wire connector that goes to the pressure transducer that you want to replace.
3. Use a 10 mm open-ended
wrench to remove the pressure
transducer.
4. Use a 10 mm open-ended
wrench to install the pressure
transducer. Tighten to 2.3 N∙m
(20 in∙lbf).

Table of Contents