Torch Connect Console
116 810410 Field Service Bulletin XPR170
Install the control PCB
1. Tilt the PCB and align the CAN connector with the hole in the panel.
2. Push the CAN connector through the hole in the panel as you push the board down.
3. Use the screws to install the PCB. Tighten to 1.1 N∙m (10 in∙lbf).
4. Install the pressure transducers. Refer to Replace a pressure transducer on page 107.
5. Connect all of the wires. Refer to Table 1 and Table 2 on page 117.
6. Install the top panel.
7. Install the manifold-side panel.
8. Supply the gas pressure to the cutting system.
9. Use the XPR web interface to make sure that the pressures are in the acceptable ranges.
For more information on the XPR web interface, refer to the Connect for
Communication in the XPR170 Instruction Manual (810060).