Torch Connect Console
XPR170 Field Service Bulletin 810410 111
Replace the solenoid valve (V11)
Refer to Torch connect console manifold side – view 2 on page 154 for
location and part number.
Remove the solenoid valve (V11)
1. Complete the following procedures:
a. Remove the power from the cutting system.
b. Remove the gas pressure from the cutting system.
c. Drain the coolant. Refer to Remove old coolant from the coolant system in the Maintenance
section in the XPR170 Instruction Manual (810060).
d. Remove the top panel.
e. Remove the side panels.
Refer to Torch connect console top panel and side panels on page 126.
Keep all nuts and screws that you remove.
2. Remove the gas supply hoses.
3. Remove the ohmic relay and bracket. Refer to Remove the ohmic relay
and bracket on page 105.
4. Remove the 2 screws that hold the manifold assembly in from the
side.
5. Remove the power connector (J19), ohmic board connector (J27) and
V1 connector (J7) from the control PCB.