Gas Connect Consoles
XPR170 Field Service Bulletin 810410 95
Replace a regulator
Refer to VWI and OptiMix gas connect console mixer, transducers, and
valves on page 150 for location and part number.
Remove a regulator
1. Complete the following procedures:
a. Remove the power from the cutting system.
b. Remove the gas and fluid pressure from the cutting system.
c. Remove the top panel.
d. Remove the manifold-side panel.
Refer to Gas connect console panels on page 100.
Keep all nuts and screws that you remove.
2. Disconnect the hoses from the push-to-connect fittings on the regulators.
3. Disconnect the 2 CAN cables from the mixer.
4. Disconnect the air hose from the push-to-connect fitting on the inlet side of the air filter.