Loading...
Gas Connect Consoles
2
XPR170 Field Service Bulletin 810410 97
Install a regulator
1. On the new regulator, install the push-to-connect fittings. Tighten to 8 N∙m (70.8 in∙lbf).
2. Use the regulator nut to install the regulator into the bracket.
3. Install the regulator and bracket assembly into the gas connect console.
4. Connect the air hose to the push-to-connect fitting on the inlet side of the air filter.
5. Carefully connect the 2 CAN cables to the mixer.
Make sure that the CAN cable from the outlet panel goes above the air
hose .
Create a loop in the CAN cable to keep the cable away from the
coolant manifold .
6. Connect the hoses to the regulators.
7. Install the side panel.
8. Install the top panel.
9. Supply the gas and fluid pressure to the cutting system.
10. Use the XPR web interface to make sure that the pressures are in the acceptable ranges. If the
pressures are not in the acceptable ranges, refer to How to set the regulators on page 98 to
calibrate the regulators.
For more information on the XPR web interface, refer to the Connect for
Communication in the XPR170 Instruction Manual (810060).