Torch Connect Console
3
XPR170 Field Service Bulletin 810410 125
Install the bottom manifold assembly
1. Install the O-ring in the groove in the inlet manifold.
2. Align the new bottom manifold assembly with the inlet manifold.
3. Use a 5 mm, hexagonal-key wrench to install the 4 screws.
4. Connect the wire connector for V11 to the control PCB.
5. Slide the manifold assembly with control PCB through the hole in the panel and into the torch
connect console.
Do not pinch the wires for V11 between the PCB and sheet metal.
6. Use a 3 mm, hexagonal-key wrench to install the 2 screws that hold the manifold assembly.
7. Connect the black, blue, and yellow tubes to the push-to-connect fittings on the manifold
assembly. Refer to How to use push-to-connect fittings on page 102.
8. Install the 2 screws on the ohmic relay side.
9. Install the ohmic relay and bracket. Refer to Install the ohmic relay and bracket on page 106.
10. Install the power connector (J19), ohmic board connector (J27) and V1 connector (J7) on the
control PCB.
11 . Install the side panels.
12. Install the top panel.
13. Install the coolant. Refer to the Coolant Installation section in the XPR170 Instruction Manual
(810060).
14. Supply the gas pressure to the cutting system.

Table of Contents

Other manuals for Hypertherm XPR170

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm XPR170 and is the answer not in the manual?

Hypertherm XPR170 Specifications

General IconGeneral
BrandHypertherm
ModelXPR170
CategoryWelding System
LanguageEnglish

Related product manuals