EasyManua.ls Logo

Hypertherm XPR170 - How to Set the Regulators; Set the N Regulator

Hypertherm XPR170
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas Connect Consoles
2
98 810410 Field Service Bulletin XPR170
How to set the regulators
This procedure is for when the regulators need to be adjusted in the field.
The N
2
and Ar OptiMix gas connect console (078633) regulators are set at Hypertherm before the
regulators are installed into the gas connect console. The regulators are set in a dynamic condition,
when gas is flowing, with 7.9 bar8.6 bar (115 psi – 125 psi) on the inlet and 6.9 bar (100 psi) on
the outlet.
There is a 1.6 mm (0.063 inch) orifice downstream.
When to adjust regulators:
If your N
2
Shield inlet (P4) pressure is above 7.5 bar (110 psi) or below 6.2 bar (90 psi).
If your Ar Shield Inlet (P4) pressure is above 7.5 bar (110 psi) or below 6.2 bar (90 psi).
Set the N
2
regulator
1. Install one of the following sets of consumables:
300 A O
2
/Air
300 A N
2
/N
2
300 A Mix/N
2
170 A O
2
/Air
170 A N
2
/N
2
170 A Mix/N
2
2. Use the XPR web interface to load one of the following processes:
2100 for the 300 A consumables
2057 for the170 A consumables
3. Remove the cover from OptiMix gas connect console.
4. Lift the N
2
regulator knob so the orange indicator is visible.
N
2
Ar

Table of Contents

Other manuals for Hypertherm XPR170

Related product manuals