Torch Connect Console
3
XPR170 Field Service Bulletin 810410 121
6. Disconnect the yellow , blue , and
black tubes from the push-to-connect
fittings on the manifold assembly. Refer to
How to use push-to-connect fittings on
page 102.
7. Use a 3 mm, hexagonal-key wrench to remove
the 2 screws that hold the manifold
assembly.
8. Slide the manifold assembly back and lift out
tubing side first.
Install the manifold assembly
1. Slide the new manifold assembly through the hole in the panel and into the torch connect
console.
2. Use a 3 mm, hexagonal-key wrench to install the 2 screws that hold the manifold assembly.
3. Connect the black, blue, and yellow tubes to the push-to-connect fittings on the manifold
assembly. Refer to How to use push-to-connect fittings on page 102.
4. Install the 2 screws on the ohmic relay side.
5. Install the ohmic relay and bracket. Refer to Install the ohmic relay and bracket on page 106.
6. Install control PCB. Refer to Install the control PCB on page 116.
7. Connect the gas supply hoses.
2
3
4
5
2
3
4
5

Table of Contents