Plasma Power Supply
46 810410 Field Service Bulletin XPR170
14. Connect all of the wire connectors.
15. Connect the CAN cable.
16. Connect the wireless antenna.
17. Connect the communication interface cables.
Make sure that you connect the in and out cables to the correct locations.
18. Install the new MAC address label from the kit on top of the old MAC address label on the rear
of the plasma power supply.
When you replace the control PCB, the information stored on the PCB
changes. This includes the MAC address that is on the new MAC address
label.
19. Install the control-side panel.
20. Install the rear panel.
21. If necessary, update the firmware in the system. Refer to the XPR Firmware Updates Field
Service Bulletin (809820).