Plasma Power Supply
58 810410 Field Service Bulletin XPR170
10. Use a long, 5 mm hexagonal-socket wrench and the hardware that comes with the contactor kit
to install the L1, L2, and L3 wires on the left and right side of the main contactor. Tighten to
9 N∙m (80 in∙lbf).
11 . Make sure that the wires with the L1, L2, and L3 labels on the right side of the main contactor
align with the wires with the L1, L2, and L3 labels on the left side of the main contactor.
12. Install the rear panel.