Gas Connect Consoles
86 810410 Field Service Bulletin XPR170
5. Disconnect the SV100 connector from the mixer module.
6. Put on hearing protection.
7. Use a blade screwdriver to push-to-disconnect the air-gas line connector, as shown in Figure 3
(left). Pressure from the screwdriver can make it easier to disconnect the connector.
Push-to-disconnect the air-gas line from the air filter inlet (Figure 3, right).
Figure 3
8. Move the air-gas line away from the mixer module.
CAUTION
HEARING LOSS CAN OCCUR FROM EXPOSURE TO LOUD NOISES
High-pressure gas in a supply-gas line can cause a loud noise when the line is disconnected.
Use hearing protection when you disconnect the air-gas line in the gas connect console. You can lose
your hearing from exposure to loud noises.