EasyManuals Logo

IBM DS5100 User Manual

IBM DS5100
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #235 background imageLoading...
Page #235 background image
Table 56. Symptom-to-FRU index (continued)
Problem
indicator Component Possible cause Possible solutions
All green LEDs
off
All FRUs Subsystem power is off. Check that all power cords are plugged in and all
power switches are on. If applicable, check that
the main circuit breakers for the rack cabinet are
turned on.
AC power failure Check the main circuit breaker and ac outlet.
Both power supply and fan
units have failed.
Replace the power supply and fan units.
Both controller circuit
breakers have tripped.
Reset the controller circuit breakers.
Chapter 6. Hardware maintenance 203

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM DS5100 and is the answer not in the manual?

IBM DS5100 Specifications

General IconGeneral
BrandIBM
ModelDS5100
CategoryStorage
LanguageEnglish

Related product manuals