Symptom/Error FRU/Action
010436XX 1. System Board
2. Hard Disk Drive
3. Hard Disk Drive Cable
0104XXXX 1. Hard Disk Drive
2. System Board
3. Hard Disk Drive Cable
0130XXXX 1. I/O Panel Assembly
2. System Board
3. Keyboard Control Card
0137XXXX 1. Any Serial Adapter
2. System Board
3. Voltage Converter
4. Any Serial Device
5. Communication Cable
0166XXXX, 0167XXXX 1. Adapter in
Communications
Cartridge
2. Communications
Cartridge
I9990301
(Startup drive not found.)
1. Start the backup
copy of the
Reference Diskette
and check if the
startup sequence is
correct.
a. Select Set
features from the
Main Menu.
b. Select Set
startup
sequence.
c. Check the list of
devices on the
screen.
I9990302
(Operating system not
found.)
1. Make sure that an
operating system is
installed.
2. Hard Disk Drive
3. System Board
4. Hard Disk Drive Cable
I998XXXX, I9990303
(See “Hard Disk Partition”
on page 96 before replacing
any FRUs.)
1. Restore the system
programs onto the
system partition.
2. Set configuration
3. Hard Disk Drive
4. System Board
5. Hard Disk Drive Cable
90 IBM Mobile Systems HMM - Volume 1