6. If you are instructed to return the power supply, follow all packaging
instructions. Use any packaging materials for shipping that are supplied to you.
Replace the power supply
7. To reinstall the PSU, or replace it with one from FRU stock, follow the
procedure in “Installing or replacing a power supply: 2076-92F” on page 79.
Removing a drive: 2076-92F
You can remove a faulty drive from a 2076-92F expansion enclosure to replace it
with a new one received from FRU stock.
Before you begin
Ensure that the drive is not a spare or a member of an array. The drive status is
shown in Pools > Internal Storage in the management GUI. If the drive is a
member of an array, follow the fix procedures in the management GUI. The fix
procedures minimize the risk of losing data or access to data; the procedures also
manage the system's use of the drive.
svc01011
Figure 89. Removed power supply
102 Storwize V7000 Gen2 and Gen2+: Quick Installation Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM StorVize V7000 Gen2 and is the answer not in the manual?

IBM StorVize V7000 Gen2 Specifications

General IconGeneral
CategoryStorage
Maximum Drives504
RAID Levels0, 1, 5, 6, 10
Operating SystemIBM Spectrum Virtualize
Power SupplyDual redundant power supplies
Input Voltage100-240 V AC
Humidity8% to 80% non-condensing
ModelStorwize V7000 Gen2
Drive InterfaceSAS
Form Factor2U
Drive Types SupportedSAS SSDs, SAS HDDs
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI
Nodes2
Operating Temperature10°C to 35°C
Non-operating Temperature-10°C to 50°C