EasyManuals Logo

IBM StorVize V7000 Gen2 User Manual

IBM StorVize V7000 Gen2
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Table 5. Steps for different installation scenarios (continued).
New system (control
enclosure only)
New system (control
enclosure and one or
more expansion
enclosures)
Adding expansion
enclosures to an
existing system
Adding control
enclosures and
expansion enclosures
to an existing system
Chapter 3,
“Configuring the
system,” on page 143
“Powering on the
system” on page 140
“Powering on the
system” on page 140
Chapter 3,
“Configuring the
system,” on page 143
“Adding a control
enclosure to an
existing system” on
page 148
1
Complete these steps for each expansion enclosure that you add.
2
Complete these steps for each control enclosure and expansion enclosure that you add.
Be familiar with the following information
v See “Caution notices for the Storwize V7000” on page x and “Danger notices for
Storwize V7000” on page xiv for a summary of the situations that can be
potentially hazardous to you. Before installing, read and understand the
following caution and danger statements.
v Use safe practices when lifting. The fully populated enclosure weighs about 37
kg (82 lbs). At least three people are required to lift and install the enclosure into
the rack or to remove an enclosure from the rack.
CAUTION:
Use safe practices when lifting.
svc00146
18-32 kg (39.7-70.5 lbs) 32-55 kg (70.5-121.2 lbs)
55 kg ( 121.2 lbs)
(27)
Also keep in mind that a rack full of equipment is extremely heavy.
DANGER: Heavy equipment–personal injury or equipment damage might
result if mishandled. (D006)
v The following general precautions should be observed, even though the
power-on steps differ slightly from the directions that you will follow for this
product:
Chapter 1. Before you begin the installation 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM StorVize V7000 Gen2 and is the answer not in the manual?

IBM StorVize V7000 Gen2 Specifications

General IconGeneral
CategoryStorage
Maximum Drives504
RAID Levels0, 1, 5, 6, 10
Operating SystemIBM Spectrum Virtualize
Power SupplyDual redundant power supplies
Input Voltage100-240 V AC
Humidity8% to 80% non-condensing
ModelStorwize V7000 Gen2
Drive InterfaceSAS
Form Factor2U
Drive Types SupportedSAS SSDs, SAS HDDs
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI
Nodes2
Operating Temperature10°C to 35°C
Non-operating Temperature-10°C to 50°C

Related product manuals