EasyManuals Logo

IBM System x3650 M4 Type 7915 Problem Determination And Service Guide

IBM System x3650 M4 Type 7915
358 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
Table 9. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number Component Test State Description Action
215-801-xxx Optical Drive
v Verify
Media
Installed
v Read/
Write Test
v Self-Test
Messages
and actions
apply to all
three tests.
Aborted Unable to
communicate
with the
device
driver.
1. Make sure that the DSA code is at the latest level. For
the latest level of DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
2. Run the test again.
3. Check the drive cabling at both ends for loose or
broken connections or damage to the cable. Replace
the cable if it is damaged.
4. Run the test again.
5. For additional troubleshooting information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Make sure that the system firmware is at the latest
level. The installed firmware level is shown in the DSA
event log in the Firmware/VPD section for this
component. For more information, see “Updating the
firmware” on page 297.
8. Run the test again.
9. Replace the DVD drive.
10. If the failure remains, go to the IBM website for more
troubleshooting information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008&lndocid=SERV-CALL.
215-802-xxx Optical Drive
v Verify
Media
Installed
v Read/
Write Test
v Self-Test
Messages
and actions
apply to all
three tests.
Aborted The media
tray is
open.
1. Close the media tray and wait 15 seconds.
2. Run the test again.
3. Insert a new CD/DVD into the drive and wait for 15
seconds for the media to be recognized.
4. Run the test again.
5. Check the drive cabling at both ends for loose or
broken connections or damage to the cable. Replace
the cable if it is damaged.
6. Run the test again.
7. Make sure that the DSA code is at the latest level. For
the latest level of DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
8. Run the test again.
9. For additional troubleshooting information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
10. Run the test again.
11. Replace the CD/DVD drive.
12. If the failure remains, go to the IBM website for more
troubleshooting information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008&lndocid=SERV-CALL.
Chapter 3. Diagnostics
165

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel C600 series chipset
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 series processors
MemoryUp to 768GB DDR3 (24 DIMM slots)
StorageUp to 16 x 2.5" or 6 x 3.5" SAS/SATA HDDs or SSDs
RAID SupportRAID 0, 1, 10
NetworkFour integrated Gigabit Ethernet ports
Power SupplyUp to two redundant hot-swap 550 W, 750 W, or 900 W power supplies
Expansion SlotsUp to 7 PCIe 3.0 slots
Storage ControllerServeRAID M5110e
ManagementIntegrated Management Module (IMM) v2

Related product manuals