Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Memory DIMM n
Status Scrub failure
detected.
(n = DIMM number)
Error A memory scrub
failure has been
detected.
6. (Trained technician only) Remove
the affected microprocessor and
check the microprocessor socket
pins for any damaged pins. If a
damage is found, replace the
system board (see “Removing the
system board” on page 290 and
“Installing the system board” on
page 292).
7. (Trained technician only) Swap the
affected microprocessor, if there are
more than one microprocessor
installed. If the problem follows the
microprocessor, replace the
affected microprocessor (see
“Removing a microprocessor and
heat sink” on page 279 and
“Installing a microprocessor and
heat sink” on page 282).
8. (Trained technician only) Replace
the system board (see “Removing
the system board” on page 290 and
“Installing the system board” on
page 292).
806f040c-2001xxxx
806f040c-2002xxxx
806f040c-2003xxxx
806f040c-2004xxxx
806f040c-2005xxxx
806f040c-2006xxxx
806f040c-2007xxxx
806f040c-2008xxxx
806f040c-2009xxxx
806f040c-200axxxx
806f040c-200bxxxx
806f040c-200cxxxx
806f040c-200dxxxx
806f040c-200exxxx
806f040c-200fxxxx
806f040c-2010xxxx
806f040c-2011xxxx
806f040c-2012xxxx
806f040c-2013xxxx
806f040c-2014xxxx
806f040c-2015xxxx
806f040c-2016xxxx
806f040c-2017xxxx
806f040c-2018xxxx
Memory DIMM
disabled for DIMM n
Status.
(n = DIMM number)
Info DIMM disabled.
1. Make sure the DIMM is installed
correctly (see “Installing a memory
module” on page 250).
2. If the DIMM was disabled because
of a memory fault (memory
uncorrectable error or memory
logging limit reached), follow the
suggested actions for that error
event and restart the server.
3. Check the IBM support website for
an applicable retain tip or firmware
update that applies to this memory
event. If no memory fault is
recorded in the logs and no DIMM
connector error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).
Chapter 3. Diagnostics 71