Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f090c-2001xxxx
806f090c-2002xxxx
806f090c-2003xxxx
806f090c-2004xxxx
806f090c-2005xxxx
806f090c-2006xxxx
806f090c-2007xxxx
806f090c-2008xxxx
806f090c-2009xxxx
806f090c-200axxxx
806f090c-200bxxxx
806f090c-200cxxxx
806f090c-200dxxxx
806f090c-200exxxx
806f090c-200fxxxx
806f090c-2010xxxx
806f090c-2011xxxx
806f090c-2012xxxx
806f090c-2013xxxx
806f090c-2014xxxx
806f090c-2015xxxx
806f090c-2016xxxx
806f090c-2017xxxx
806f090c-2018xxxx
Memory DIMM for
DIMM n Status has
been automatically
throttled.
(n = DIMM number)
Info A memory DIMM
has been
automatically
throttled.
No action; information only.
806f0a0c-2001xxxx
806f0a0c-2002xxxx
806f0a0c-2003xxxx
806f0a0c-2004xxxx
806f0a0c-2005xxxx
806f0a0c-2006xxxx
806f0a0c-2007xxxx
806f0a0c-2008xxxx
806f0a0c-2009xxxx
806f0a0c-200axxxx
806f0a0c-200bxxxx
806f0a0c-200cxxxx
806f0a0c-200dxxxx
806f0a0c-200exxxx
806f0a0c-200fxxxx
806f0a0c-2010xxxx
806f0a0c-2011xxxx
806f0a0c-2012xxxx
806f0a0c-2013xxxx
806f0a0c-2014xxxx
806f0a0c-2015xxxx
806f0a0c-2016xxxx
806f0a0c-2017xxxx
806f0a0c-2018xxxx
An Over-Temperature
condition has been
detected on the
DIMM n Status.
(n = DIMM number)
Error An
over-temperature
condition has
occurred for DIMM
n.
(n = DIMM
number)
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that the
air baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2. Make sure that ambient
temperature is within the
specifications.
3. If a fan has failed, complete the
action for a fan failure.
4. Replace DIMM n.
(n = DIMM number)
800b010c-2581xxxx Backup Memory
redundancy lost has
asserted.
Error Redundancy has
been lost.
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirroring in the Setup
utility.
Chapter 3. Diagnostics 77