Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
800b030c-2581xxxx Backup Memory
sufficient resources
from redundancy
degraded has
asserted.
Warning There is no
redundancy. The
state has been
transitioned from
redundancy to
sufficient
resources.
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirroring in the Setup
utility.
800b050c-2581xxxx Backup Memory
insufficient resources
has asserted.
Error There is no
redundancy and
insufficient to
continue operation.
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirroring in the Setup
utility.
Storage messages
806f000d-0400xxxx
806f000d-0401xxxx
806f000d-0402xxxx
806f000d-0403xxxx
806f000d-0404xxxx
806f000d-0405xxxx
806f000d-0406xxxx
806f000d-0407xxxx
806f000d-0408xxxx
806f000d-0409xxxx
806f000d-040axxxx
806f000d-040bxxxx
806f000d-040cxxxx
806f000d-040dxxxx
806f000d-040fxxxx
806f000d-040fxxxx
Drive n has been
added.
(n = Drive number)
Info A drive has been
added.
No action; information only.
816f000d-0400xxxx
816f000d-0401xxxx
816f000d-0402xxxx
816f000d-0403xxxx
816f000d-0404xxxx
816f000d-0405xxxx
816f000d-0406xxxx
816f000d-0407xxxx
816f000d-0408xxxx
816f000d-0409xxxx
816f000d-040axxxx
816f000d-040bxxxx
816f000d-040cxxxx
816f000d-040dxxxx
816f000d-040exxxx
816f000d-040fxxxx
The Drive n Status
has been removed
from unit.
(n = hard disk drive
number)
Error A drive has been
removed.
1. Reseat hard disk drive n.
(n = hard disk drive number). Wait
1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware
and RAID controller firmware is at
the latest level.
4. Check the SAS cable.
78 IBM System x3650 M4 Type 7915: Problem Determination and Service Guide