ACC set mode (Continued)
SEND Relay Type
MOS-FET
Selects the switching relay type for [RELAY] from
Reed and MOS-FET.
Select the suitable relay type when connecting a
non-Icom linear amplifier.
Reed : Use mechanical relay.
(16 V DC/0.5 A max.: default)
MOS-FET : Use semiconductor type relay.
(250 V/200 mA max.)
External Meter Output
Auto
Selects the desired item for an external meter
indication.
Auto : Outputs the receiving signal strength level
during receive, and outputs the selected
level (selected with [METER]), during
transmit. (default)
S : Outputs the receiving signal strength level
during receive.
Po : Outputs the transmitting power level
during transmit.
SWR : Outputs the VSWR level during transmit.
ALC : Outputs the ALC level during transmit.
COMP : Outputs the compression level during
transmit.
• V : Outputs the drain terminal voltage of the
final amplifier MOSFETs.
I : Outputs the drain current of the nal
amplifier MOSFETs.
External Meter Level
50
%
Sets the output level for an external meter indication
with in 0% to 100% range in 1% steps.
Approximately 2.5 V at 50% (default) setting for
full-scale indication. (4.7 kø impedance)
REF Adjust
50
% (Example)
Adjusts the internal reference signal frequency
within 0% to 100% range in 1% steps during
frequency calibration.
NOTE: Default setting is different for each
transceiver.
133
10
SET MODE