166
12
CONTROL COMMAND
12
D Data content description
Operating frequency
Command: 00, 03, 05, 1C 03
q
XXXXX
we
X
rt
XX00
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–6
1 MHz digit: 0–9
1000 MHz digit: 0
(Fixed)
100 MHz digit: 0
(Fixed)
Operating mode
Command: 01, 04, 06
q
XXXX
w
q Operating mode w Filter setting
00: LSB 05: FM 01: FIL1
01: USB 07: CW-R 02: FIL2
02: AM 08: RTTY-R 03: FIL3
03: CW 12: PSK
04: RTTY 13: PSK-R
Filter setting (w) can be skipped with command 01
and 06. In that case, “FIL1” is selected with command
01 and the default filter setting of the operating mode
is selected with command 06, automatically.
Memory keyer contents
Command: 1A 02
X
q: Channel data
01M1
02M2
03M3
04M4
w&1: Text data
XXX
……
XX
Characters code
Character ASCII code Description
0–9 30–39 Numerals
A–Z 41–5A Alphabetical characters
space 20 Word space
/ 2F Symbol
? 3F Symbol
, 2C Symbol
. 2E Symbol
@ 40 Symbol
^ 5E
Example:
To send BT, enter ^BT
2A Inserts contest number (can be
used for 1 channel only)
Band stacking register
Command: 1A 01
q
XXXX
w
q Frequency band code
Code Freq. band Frequency range (unit: MHz)
01 1.8 1.800000– 1.999999
02 3.5 3.400000– 4.099999
03 7 6.900000– 7.499999
04 10 9.900000–10.499999
05 14 13.900000–14.499999
06 18 17.900000–18.499999
07 21 20.900000–21.499999
08 24 24.400000–25.099999
09 28 28.000000–29.999999
10 50 50.000000–54.000000
11 GENE Other than above
w Register code
Code Registered No.
01 1 (latest)
02 2
03 3 (oldest)
For example, when reading the oldest contents in the
21 MHz band, the code “0703” is used.
When sending the contents, the following code should
be added after code w.
eui, o!0!1!3 !4!6
XX... XXXXXXXXXXXXXXXXXXXXXX XX
q, w
eu Operating frequency setting
See “• Operating frequency.
i, o Operating mode setting
See “• Operating mode.
!0 Data mode setting
1 byte data (XX)
XX
!0
0: OFF, 1: TONE, 2: TSQL
0: OFF, 1: DATA 1, 2: DATA 2, 3: DATA 3
!1!3 Repeater tone frequency setting
!4!6 Tone squelch frequency setting
See “• Repeater tone/tone squelch setting.
Clock 2 offset time setting
Command: 1A 05 0056
X
Shift direction
00: + (plus)
01: − (minus)
Offset time
0000−2400
XXX XX