Data content description (continued) D
Offset frequency setting
Command: 1A 05 0065, 0066, 0072
1 kHz digit: 0–9
100 Hz digit: 0 (fixed)
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–9
1 MHz digit: 0–9
Direction:
00=+ direction
01=– direction
q
0XXXXXX
we
0
r*
*No need to enter for transverter offset frequency setting.
Transverter offset only. Fix to ‘0’ for split offset setting.
Codes for memory name, opening message and
CLOCK2 name contents
Command: 1A 05 0052, 0057
To send or read the desired memory name settings,
the character codes, instructed codes for memory
keyer contents, and follows are used.
Character’s code— Alphabetical characters
Charac-
ter
ASCII
code
Charac-
ter
ASCII
code
a–z 61–7A
Character’s code— Symbols
Charac-
ter
ASCII
code
Charac-
ter
ASCII
code
! 21 # 23
$ 24 % 25
& 26 ¥ 5C
? 3F 22
27 ` 60
+ 2B 2D
: 3A ; 3B
= 3D < 3C
> 3E ( 28
) 29 [ 5B
] 5D { 7B
} 7D | 7C
_ 5F 7E
@ 40
Command Set item/Available characters
1A00
Memory name
All characters are available.
1A05 0052
Opening message
Capital letters, numerals, some symbols (− /
. @) and space are available.
1A05 0057
CLOCK 2 name
Capital letters, small letters, numerals,
some symbols (! # $ % & ¥ ? " ’ ` ^ + – /
. , : ; = < > ( ) [ ] { } ¦ _
@) and space are
available.
Color setting
Command: 1A 05 0106, 0107, 0140, 0149, 0150,
0151, 0152, 0154, 0159, 0160,
0161, 0162, 0180
q
0 XXX0XXX0 XXX
werty
R (Red)
0000–0255
G (Green)
0000–0255
B (Blue)
0000–0255
Bandscope edge frequency setting
Command: 1A 05 0115, 0116, 0117, 0118, 0119,
0120, 0121, 0122, 0123, 0124,
0125, 0126
1 kHz: 0–9
100 Hz: 0 (fixed)
100 kHz: 0–9
10 kHz: 0–9
10 MHz: 0–6
1 MHz: 0–9
1 kHz: 0–9
100 Hz: 0 (fixed)
100 kHz: 0–9
10 kHz: 0–9
10 MHz: 0–6
1 MHz: 0–9
q
X XXXXXXXXXXX
werty
Lower edge Higher edge
Data mode with lter width setting
Command: 1A 06
q
XX XX
w
00=Data mode OFF
01=FIL1
02=FIL2
03=FIL3
00=Data mode OFF
01=Data mode 1 (D1)
02=Data mode 2 (D2)
03=Data mode 3 (D3)
• Codes for CW message content
Command : 17 Up to 30 characters
To send CW messages, the following character codes
are used.
“FF” stops sending CW messages.
“^” is used to transmit a string of characters with
no inter-character space.
Characters code
Charac-
ter
ASCII
code
Charac-
ter
ASCII
code
0–9 30–39 27
A–Z 41–5A ( 28
a–z 61–7A ) 29
/ 2F = 3D
? 3F + 2B
. 2E 22
2D @ 40
, 2C Space 20
: 3A
167
12
CONTROL COMMAND