168
12
CONTROL COMMAND
12
• Repeater tone/tone squelch frequency setting
Command: 1B 00, 1B 01
100Hz digit: 0–2
10 Hz digit: 0–9
1 Hz digit: 0–9
0.1 Hz digit: 0–9
Fixed digit: 0*
Fixed digit: 0*
q*
00XXX
we
X
*Not necessary when setting a frequency.
• Band edge frequency setting
Command 02*, 1E 01, 1E 03
q
XXX
w ertyuio!0!1!2
XXXXXXXXX2DX XXXXXXXXX
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–6
1 MHz digit: 0–9
1000 MHz digit: 0 (fixed)
100 MHz digit: 0 (fixed)
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–6
1 MHz digit: 0–9
1000 MHz digit: 0 (fixed)
100 MHz digit: 0 (fixed)
Separator (fixed)
Lower edge Higher edge
Edge number*: 01–30
* Edge number setting is not necessary with
command 02.
• RIT frequency settings
Command : 21 00
10 Hz: 0–9
100 Hz: 0–9
1 Hz: 0–9
1 kHz: 0–9
XXXX XX
00: + (plus)
01: – (minus)
• Main or Sub band’s frequency settings
Command : 25
X X X X X X X X X X 0 0
00: MAIN
01: SUB
Operating frequency data
(See p. 166)
• Main or Sub band’s operating mode and filter
settings
Command : 26
Both data and filter settings can be skipped. In that
case, “DATA OFF” and the default filter setting of the
operating mode is automatically selected.
X X X X X XX X
Operating mode setting
(see p. 166)
Filter setting
(see p. 167)
Data mode setting
(see p. 167)
00: MAIN
01: SUB
• RX HPF/LPF setting for each operating mode
Command : 1A 05 0001, 0004, 0007, 0010, 0011,
0012
X X X X
LPF (Upper edge)
HPF (Lower edge)
*The value of the HPF should be smaller than the LPF.
HPF
00: Through
01~20: 100~2000 Hz
LPF
05~24: 500~2400 Hz
25: Through
• SSB transmission passband width settings
Command : 1A 05 0019, 0020, 0021
XX
Higher edge: 0=2500 Hz
1=2700 Hz
2=2800 Hz
3=2900 Hz
Lower edge: 0=100 Hz
1=200 Hz
2=300 Hz
3=500 Hz