IDEC SmartRelay Manual 154
4.4.10 Dual-function switch
Short description
Switch with two different functions:
• Pulse switch with off-delay
• Switch (permanent lighting)
Symbol in
IDEC 
SmartRelay
Wiring Description
Input Trg A signal at input Trg (Trigger) 
sets output Q (permanent light) 
or resets it with off-delay. When 
active, output Q can be reset with 
a signal at input Trg.
Input R A signal at input R resets the cur-
rent time T
a
 and the output.
Parameter T represents the time after which 
f the output is reset (output signal 
transition 1 to 0).
T
L
 represents the time during 
which the output must be set to 
enable the permanent lighting 
function.
T
!
 represents the preset time for 
the start of the off-warning signal.
T
!L
 represents the length of the 
off-warning period.
Retentivity:  
/ = No retentivity 
R = The status is retentive.
Output Q A signal at Trg switches on out-
put Q. Depending on the length 
of the input at Trg, the output is 
switched off again or switched on 
permanently, or it is reset with a 
further signal at Trg.