IDEC SmartRelay functions
IDEC SmartRelay Manual 176
Press
B15 2
G_T
=01:00s
Time interval for pulses
(example)
Note
The “seconds” timebase is here set as permanent default.
When you preset a time G_T of 1 s, the IDEC SmartRelay returns
the current frequency in parameter f
a
in Hz.
View in parameter assignment mode (example):
B15
On =0009
Off =0005
fa =0010
On threshold
Off threshold
Q = 1 (f
a
> On)
Note
f
a
always represents the total pulses measured per time unit G_T.