IDS X-Series Installer Manual 700-398-02H Issued July 2013
LOCATION 301 Global Reporting Code 2
This location is used to configure global reporting codes to be used in the event that Neither Contact ID or SIA
formats are used. These codes will be used when any of the other formats in Communications Setup -
Advanced have been selected.
Sub-location 1 is Battery Low
A low battery condition is reported when the battery voltage drops below 11V for a period longer
than 5 minutes or immediately if it drops below 10V. Option 5 in Table 41 needs to be enabled..
Sub-location 2 is Battery Restored
This code is reported once the battery voltage rises above 12V for a period of five minutes. Option
8 in Table 42 needs to be enabled.
Sub-location 3 is Aux 12V Fuse Failed
This code is reported when there is a problem with the Aux 12V. Option 6 in Table 41 needs to be
enabled.
Sub-location 4 is Aux 12V Fuse Restored
This code is reported when the Aux 12V fuse has been replaced.
Sub-location 5 is Installer reset required
This code is reported when enabled in location 211 – 218 and the alarm is triggered.
Sub-location 6 is Installer reset Restored
This code is reported when Installer reset is enabled in location 211 – 218 and the alarm is
triggered and the installer code has been entered to enable the system to be armed.
Sub-location 7 is Box Tamper
This code is reported when the box tamper contacts are open for a period exceeding 200 ms.
Option 8 in Table 41 needs to be enabled.
Sub-location 8 is Box Tamper Restored
This code is reported once the box tamper is closed.
Enter a 2-digit reporting code for each of the 8 sub-locations and program as a 16-digit string,
followed by the [*] key.
NOTE: When programming using the string method, reserved sub-locations will still need data to be inputted
into them to maintain the 16-digits needed to successfully program. Inputting data into a reserved sub-location
will not affect the value of the sub-location. Reserved sub-locations have a value of 00.
[INSTALLER CODE] [*] [3] [0] [1] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*]
The valid data range is: 01-FF, with 00 to disable.
If any of the sub-locations are disabled here, then the reporting codes will not report – even if they are enabled
Refer to Using Sub-locations to see how to scroll through sub-location using the [*] key.
NOTE: The values are hexadecimal. Refer to Table 3 on how to program hexadecimal values.
LOCATION 302 Global Reporting Code 3
This location is used to configure global reporting codes to be used in the event that Neither Contact ID or SIA
formats are used. These codes will be used when any of the other formats in Communications Setup -
Advanced have been selected.
Sub-location 1 is Bus Device Tamper
This code is reported when there is a tamper condition on any external device attached to the
keypad bus. Option 1 in Table 42 needs to be enabled.
Sub-location 2 is Bus Device Tamper Restored
This code is reported when the tamper condition on any external device attached to the keypad
bus is corrected.
Sub-location 3 is Bus Peripheral Communication Fail
This code is reported when any external device attached to the keypad bus goes missing. Option 2
in Table 42 needs to be enabled..
Sub-location 4 is Bus Peripheral Communication Restored
This code is reported when any external device attached to the keypad bus is restored.