98
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
Victrix Extra 35 Plus
Id
Parameter
Parameter Description Range Default
Customised
value
G. Gas type Display gas type: nG (Methane) or LG (LPG) nG-LG-AP nG
n. Boiler model Dene the boiler model 0-20* 1
S.0
Minimum no. of
fan revs
Denes the operating speed of the fan at minimum output 700-3000 2200
S.1
Maximum no. of
fan revs
Denes the operating speed of the fan at maximum output 2000-8300 7200
S.2
Ignition phase
no. of fan revs
Denes the operating speed of the fan during the ignition
phase
2000-4500 3800
F.0 Flue length Denes the length of the ue (Parag. 3.12) 0-2 0
F.1
Presence of
clapet valve on
ue gas (C
(10)
-
C
(12)
)
If present, automatic corrections are made to the fan's
operating range
0-1 0
* : 0 cannot be used; from 4 to 20 cannot be used; only 1-2-3 available.
If parameters are changed, the anomalies "E62" or "E72" will appear and automatic calibration will be required.