Translation of the original operating instructions
UL3000 Fab ULTRA
Helium Leak Detector with ULTRATEST
Sensor Technology
iinb73en1-09-(2109)
Catalog No.
550-260
From software version
1.51 (Operating unit)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Inficon UL3000 Fab ULTRA and is the answer not in the manual?

Inficon UL3000 Fab ULTRA Specifications

General IconGeneral
TypeHelium Leak Detector
Detection MethodMass Spectrometer
Accuracy±10% of reading
Operating Humidity10% to 90% RH (non-condensing)
Detectable GasesHelium
Minimum Detectable Leak Rate (Helium)5 x 10-12 mbar l/s
Sensitivity5 x 10-12 mbar l/s
Test Port PressureUp to 15 mbar
Response TimeLess than 1 second
Operating Temperature10°C to 40°C
Power Requirements100-240 VAC, 50/60 Hz
Communication InterfacesRS-232, USB, Ethernet
ApplicationsSemiconductor
Measurement Range1 x 10⁻¹² to 1 x 10⁻² mbar·l/s

Summary

1 About this manual

1.1 Target groups

Manual intended for operators and technical specialists.

1.2 Warnings

Explanation of danger, warning, caution, and notice levels.

1.3 Definition of terms

Defines terms like 'helium' and 'hydrogen' usage.

2 Safety

2.1 Intended use

Defines the device's purpose and lists misapplications.

2.2 Duties of the operator

Operator responsibilities regarding manual and safety.

2.3 Owner requirements

Requirements for companies and personnel regarding safe operation.

2.4 Dangers

Details dangers from electric power, explosion, suction, and bursting objects.

3 Scope of delivery, Transport, Storage

Scope of delivery

Lists items included with the device.

Transport

Instructions for safely transporting the device.

Storage

Guidelines for storing the device.

4 Description

4.1 Function

Explains the leak detector's purpose and methods.

4.2 Operation modes

Introduces Vacuum, Sniffing, and Auto Leak Test modes.

4.3 Device setup

Overview of device setup and components.

4.4 Technical specifications

Lists detailed technical specifications of the device.

4.5 Factory settings

Lists the default configuration settings.

5 Installation

5.1 Setup

General setup instructions and safety precautions.

5.2 Connect the supplied accessories

Instructions for attaching device accessories.

5.4 Connecting to the power supply system

How to connect the device to power.

5.5 Checking the operation of the device

Steps to verify the device is working correctly.

6 Operation

6.1 Switching on

Steps and precautions for switching on the device.

6.2 Basic settings

Overview of initial device configuration.

6.3 Settings for the measurements

Configuration options for measurements.

6.4 Measuring

Step-by-step guide for performing measurements.

6.5 Measuring helium ambient concentration

Measuring ambient helium levels.

6.6 Measurement data

Managing and exporting measurement data.

6.7 Information

Accessing device and measurement information.

6.8 Log

Accessing device logs.

6.9 Device settings

Managing device configuration parameters.

6.10 Updating the software

Instructions for updating device software.

6.11 Use external monitor

Connecting and using an external monitor.

6.12 View vacuum diagram

Displaying the vacuum system diagram.

6.13 Resetting to factory settings

Restoring device to factory default settings.

6.14 Logging off from the device

How to log out of the device.

6.15 Switching off the device

Procedures for safely switching off the device.

7 Warning and error messages

Warnings

Explains warning messages and their handling.

Error messages

Explains error messages and their handling.

Active errors and warnings

Shows where to view active errors/warnings.

Confirmed warnings

Shows acknowledged but unrectified warnings.

Reference on the display

Where to find an overview of errors/warnings.

Special case

Handling voltage supply issues.

8 Cleaning and maintenance

8.1 Cleaning the housing

Instructions for cleaning the device housing.

8.2 Change the filter mat inside the tool box

Steps to replace the filter mat in the tool box.

8.3 Replacement of the filter mat on the bottom of the device

Steps to replace the filter mat on the device bottom.

8.4 Replacing the SL200 sniffer line filter

Steps to replace the SL200 sniffer line filter.

8.5 Replacing the SL3000 sniffer line filter

Steps to replace SL3000 sniffer line filter.

8.6 Creating screenshots

How to save screen captures to a USB stick.

8.7 Sending for repair or maintenance

Information on sending the device for service.

8.8 Maintenance plan

Overview of scheduled maintenance tasks.

9 Decommissioning the measuring instrument

9.1 Disposing of the device

Proper disposal instructions for the device.

9.2 Sending in the device

Procedures for sending the device for service.

10 Accessories and interfaces

10.1 Accessories and spare parts

List of available accessories and part numbers.

Helium bottle holder

Details on the Helium bottle holder accessory.

Remote control RC1000C and RC1000WL

Information on remote controls.

Test chamber TC1000

Information about the TC1000 test chamber.

10.2 I/O module

Information on the I/O module.

10.3 Bus module

Information on bus modules.

10.4 Network

Network configuration and operation.

10.4.1 Operate leak detector via web browser (LAN)

Operating the device via web browser using LAN.

10.4.2 Operate leak detector via web browser (wireless LAN)

Operating the device via web browser using WLAN.

11 Appendix

11.1 Menu path

Overview of menu navigation paths.

11.1.1 Diagnostics

Paths for diagnostic functions.

11.1.2 Settings

Paths for various setting menus.

11.1.3 Information

Paths to access device information.

11.2 CE Declaration of Conformity

CE conformity statement.

11.3 Certificate (TÜV Rheinland)

TÜV Rheinland certification document.

11.4 RoHS

Restriction of Hazardous Substances compliance.