Goodrive300-LIFT series inverter Function parameters
-65-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P11.10
Overload alarm
detection
time
overload alarm function.
Setting range: 0x0000x131
LED ones:
0: Motor overload alarm, relative to the rated
current of the motor
1: Inverter overload alarm, relative to the rated
current of the inverter
LED tens:
0: The inverter continues working after
overload/underload alarm.
1: The inverter continues working after
underload alarm reporting but it stops
running upon an overload fault.
2: The inverter continues working after overload
alarm reporting but it stops running upon an
underload fault.
3: The inverter stops running after
overload/underload alarm reporting.
LED hundreds:
0: Detection all the time
1: Detection in constant running
Setting range of P11.09: 100%200%
Setting range of P11.10: 0.13600.0s
1.0s
P11.11
Motor overload
selection
0: No protection
1: Common motor
2: Variable-frequency motor
2
P11.12
Motor overload
protection
coefficient
20.0%120.0%
100.0
P11.13
Speed deviation
detection
0.050.0%
10.0%
P11.14
Speed deviation
detection time
This parameter is used to set the speed
deviation detection time.
Note: Speed deviation protection is disabled
when P11.14 is set to 0.0.
1.0s